BQG-2118 Industrial Online Zirconia Oxygen Analyzer

Technical indexes


1.Measuring range: 0~20.6%02

2.Accuracy: ≤±2%FS

3.Temperature of flue gas measured: ≤600℃(low temperature type)600~800(high temperature type)

4. Excess air coefficient of flue gas measured: 0.1-99                    

5. Response time: ≤ 3 seconds (90% response)

6. Current output: 0~10mADC or 4-20mADC

7. Power supply: 220V±10% 50HZ± 5%

8.Working conditions: ambient temperature: 0~50  relative humidity:<85%

9.Heating-up time of the heater of zirconia detector: Approx 20 minutes  

10.Overall dimension and dimension of the hole



Type

Overall dimension mm

Dimension of the hole mm (height * width)

Horizontal (H)

160x80x120

152+1×76+1

Vertical (Z)

80x160x120

   76+1×152+1

Square (Q)

160x160x200

    152+1×152+1

Wall mounting (G)

220 x 170 x 75 (height x width x thickness)

BQG-2118 zirconia oxygen analyzer is practical and reliable on-line automatic oxygen analyzer. Its measurement and display system consists of an oxygen detector (sensor) and a display instrument (transmitter). The detector is made of heat-resisting and anti-corrosion materials and can be directly inserted into flues for measurement of oxygen. The display instrument adopts single-chip control and can be used in combination with various electric unit combination instrument, main display recorder instruments and distributed control systems (DCS).

Zirconia oxygen analyzer is used for rapid and accurate on-line measurement and analysis of the oxygen contents in the flue gas produced by combustion equipment, such as boilers, furnaces and heaters, so as to realize control of low-oxygen combustion, energy saving and pollution treatment. 

Features


The sensor is made of heat-resisting and anti-corrosion materials with high reliability.

With a special structural design, this analyzer doesnt need external air pump, and the reference air can realize 

convection by itself.

The sensor has a standard air interface, which enables calibration check on the site and provides convenient

maintenance.

It adopts single-chip control and data processing with quick response, accurate measurement and stable

performance.

上海博取儀器有限公司
  • 聯(lián)系人:邢銀鳳
  • 地址:上海浦東新區(qū)秀沿路118號
  • 郵箱:2355456200@qq.com
  • 手機:15021885022
關(guān)注我們

歡迎您關(guān)注我們的微信公眾號了解更多信息

掃一掃
關(guān)注我們
版權(quán)所有©2025上海博取儀器有限公司All Rights Reserved    備案號:滬ICP備08017338號-29    sitemap.xml    總訪問量:672041
管理登陸    技術(shù)支持:儀表網(wǎng)
女性| 丹凤县| 呈贡县| 马尔康县| 凉城县| 双鸭山市| 长汀县| 盐池县| 罗江县| 台前县| 宝清县| 镇康县| 泗阳县| 雷波县| 锡林浩特市| 翁牛特旗| 西昌市| 乌恰县| 新巴尔虎左旗| 九寨沟县| 古交市| 文登市| 扶风县| 娱乐| 西青区| 珲春市| 福建省| 上虞市| 鄂伦春自治旗| 永春县| 武宁县| 城市| 永登县| 黄石市| 江阴市| 江油市| 山东| 呼伦贝尔市| 时尚| 镇平县| 措勤县|